24 Nov 2026 By CISO Consulting team 0 views 4 min read

NCA OTCC Checklist for OT Security Training: 12 Facts

OT security training lands better when engineers arrive with real facts about their own plant. This twelve-item checklist helps you gather them in a day and map each to an NCA OTCC control family.

Two engineers reviewing a network diagram on a tablet beside a control panel in an industrial plant.
In this article
  1. How to use this checklist
  2. Group 1: Assets and inventory
  3. Group 2: Network architecture and zones
  4. Group 3: Remote access and vendor connections
  5. Group 4: Monitoring, safety and response
  6. Mapping your answers to OTCC control families
  7. Common mistakes when preparing
  8. How CISO Consulting can help

Operational technology training pays off when engineers arrive with facts about their own plant instead of generic examples. This NCA OTCC checklist for OT security training lists twelve items you can gather in a day, grouped by topic, with a line on why each matters. Where we mention a control family, we refer to the NCA OT Cybersecurity Controls (OTCC) without citing control numbers, so confirm exact references against the current NCA document.

You do not need perfect answers. A partial, honest answer such as "we do not know" is useful, because it shows the trainer and your engineers where to focus.

How to use this checklist

Assign one owner per group: an OT engineer for assets and zones, a network or security lead for remote access and vendors, and a plant manager for safety and operations. Keep the answers in one shared document. Mark each item as known, partly known or unknown.

Group 1: Assets and inventory

  1. Asset list as it stands today. Gather whatever inventory exists: spreadsheets, vendor lists, historian exports. It matters because the OTCC asset management expectations start from knowing what you own.
  1. Criticality of each process area. Note which units would stop production or affect safety if lost. It matters because training exercises and risk decisions should focus on the systems that carry the most consequence.
  1. Unsupported or unpatchable devices. List controllers, HMIs and servers running end-of-life software or that cannot be patched without a shutdown. It matters because these shape your compensating controls and the OTCC vulnerability and change management discussion.

Group 2: Network architecture and zones

  1. Current network diagram. Bring the latest diagram, even if it is outdated, and mark where you believe it differs from reality. It matters because training on the zones and conduits model works best against your own layout.
  1. Boundary between IT and OT. Document the firewalls, data diodes, jump hosts or shared services that sit between corporate and plant networks. It matters because network segmentation and boundary protection are central OTCC topics.
  1. Existing zones and the traffic between them. Note any grouping of devices by function, and the flows you know are required, such as historian replication. It matters because defining conduits means knowing which communication is necessary.

Group 3: Remote access and vendor connections

  1. Every remote access path. List VPNs, remote desktop tools, modems and cellular gateways, including ones installed for a single project. It matters because undocumented paths are a common blind spot and relate directly to OTCC access control requirements.
  1. Vendor and integrator connections. Record which suppliers connect, how, who approves it and whether sessions are logged. It matters because the training covers remote access and vendor connections, and your answers make the discussion concrete.
  1. Accounts and authentication on OT systems. Note shared accounts, default credentials and where multi-factor authentication is or is not possible. It matters because identity and access management gaps are easy to find and costly to leave.

Group 4: Monitoring, safety and response

  1. Current visibility and logging. State what you monitor today, such as firewall logs, historian alarms or any passive monitoring tool. It matters because monitoring in OT must avoid disturbing live processes, so the starting point defines the realistic next step.
  1. Safety and operational constraints. Record maintenance windows, systems that must never be scanned actively, and safety instrumented system boundaries. It matters because safe testing and asset discovery depend on these limits, and engineers should state them before any lab discussion.
  1. Incident response arrangements. Note who decides to isolate a system, how operations and security communicate, and whether any plant-specific playbook exists. It matters because incident response in operational environments differs from IT, and roles need to be clear before an event.

Mapping your answers to OTCC control families

Once you have the twelve items, group them by theme so the gaps are easy to read:

  • Items 1 to 3: asset management, change and vulnerability handling.
  • Items 4 to 6: network segmentation and boundary protection.
  • Items 7 to 9: remote access, third-party connections and identity and access management.
  • Items 10 to 12: monitoring, safety-aware operations and incident response.

Treat this as a working map, not a compliance conclusion. It shows where your evidence is strong and where an engineer needs to learn more. Because NCA ECC also applies to many organizations, note where an item relates to enterprise controls as well.

Common mistakes when preparing

  • Waiting for a complete asset inventory before starting. A partial list is enough for training.
  • Letting IT alone answer. Plant engineers know which constraints are real.
  • Omitting vendor paths that are rarely used. Rare paths still count.
  • Sanitizing the answers. The exercise only helps if the gaps are visible.

How CISO Consulting can help

Our Industrial & OT Security Training is built for plant, facility and engineering teams. The course covers OT architecture and the zones and conduits model, safe asset discovery and passive monitoring, remote access and vendor connections, incident response in operational environments, and mapping to the NCA OT Cybersecurity Controls.

We start by agreeing the audience, level, language and dates. We then tailor examples and labs to your institution, which is where your completed checklist is most useful. Delivery is instructor-led, on site or online, with self-paced lessons where offered, and training runs from one to five days. Learners are assessed through quizzes or practical exercises and receive certificates with CPE hours.

Participants receive course materials and scenario exercises, an OT security checklist, and results per learner. Foundation suits people new to the topic, Intermediate suits those who do the work, and Advanced suits leads and specialists, and we can mix levels in one program after a short skills check.

If you would like to bring your twelve facts into a session, approved clients can order seats or a whole cohort from Training in the client portal, or ask for a quote for an on-site session.

Tags: NCA OTCC OT security industrial control systems security training checklist Saudi Arabia OTCC
Readiness self-check

How ready are you? Find out in two minutes

Answer a few questions for your framework. You get a score, your biggest gaps and — if you want it — a detailed assessment from our team.

Ready to talk about your compliance?

Tell us where you stand. We will show you the shortest path to what your regulator expects.

Regulatory updates in your inbox

SAMA, NCA and SDAIA changes and what they mean for your institution — once a month.

E-mails in

We confirm by e-mail; unsubscribe any time. Manage your subscription · Past issues

Schedule a Free Assessment