Operators of critical infrastructure in the Kingdom often arrive at an assessment with well-written security operations policies and still struggle. The reason is rarely the policy set. NCA ECC Domain 5 compliance depends on whether your logging architecture can show, from evidence, what happened on a given system at a given time. If it cannot reconstruct a timeline, detection and response cannot be demonstrated, whatever the documents say.
This article describes three common mistakes in log-source coverage, the way assessors tend to probe each one, and a short "do this instead" for every mistake. The patterns are drawn from general practice in security operations, and they apply to any operator preparing for assessment against the National Cybersecurity Authority (NCA) Essential Cybersecurity Controls.
Mistake 1: Collecting logs from the wrong layer
Many programmes onboard the sources that are easy to connect: firewalls, a handful of servers, perhaps the antivirus console. These produce volume, so the dashboards look healthy. But the sources that explain an intrusion are often missing: identity and directory services, privileged access tools, remote access gateways, and the systems that sit closest to critical operations.
An assessor will typically pick an asset or an account and ask what evidence exists of its activity. If the answer is only network perimeter data, the timeline has a hole where authentication and privilege use should be.
Do this instead
- List your critical assets and the identity, access and administration systems that touch them.
- Map each one to a log source and mark whether it is onboarded, partially onboarded or absent.
- Onboard authentication, privileged activity and remote access logs before adding more network volume.
Mistake 2: Logs that cannot be correlated in time
Even when the right sources are present, timelines break when clocks disagree. Devices that drift by minutes, mixed time zones, and inconsistent timestamp formats make it impossible to put events from different systems into one sequence. Parsing problems compound this: if fields such as user, source address or host are not normalised, an analyst cannot follow one actor across systems.
Assessors test this by asking you to walk through a sample event across two or three sources. Hesitation at this step is a strong signal that detection relies on individual effort rather than architecture.
Do this instead
- Enforce a single authoritative time source across all log-producing systems and verify it periodically.
- Standardise time zone and timestamp format at the collection layer.
- Normalise the core fields (user, host, source, action, outcome) so one query can follow an actor across sources.
- Run a monthly check that sampled events from different sources line up.
Mistake 3: Retention and integrity treated as storage questions
The third gap is treating retention as a disk-space decision. Logs are kept for whatever period the storage allows, held in places where administrators can alter them, and not checked for gaps. When an assessor asks for events from several months earlier, the operator discovers that a source stopped sending weeks ago, or that older data was rolled off.
Silent log-source failure is the most damaging version of this. A source that stops reporting looks, on a dashboard, exactly like a quiet system.
Do this instead
- Set retention periods by requirement and risk, document them, and confirm they match the NCA requirements and any sector rules that apply to you.
- Restrict write and delete access to log stores and record who holds it.
- Alert on sources that stop sending, so a gap is detected in hours rather than found during an assessment.
- Test retrieval of older events at least once before the assessment.
Mistake 4: Detection use cases that do not match the log sources
A related error sits between logging and monitoring. Detection rules are often written from a generic library and assume sources that are not onboarded. The rules exist on paper but never fire, because the data they depend on never arrives.
Do this instead
- For every detection use case, record the log sources it requires and confirm each is present.
- Retire or defer rules that have no data behind them, and prioritise those tied to your critical assets.
- Rehearse a realistic scenario and check that the evidence trail supports the detection and the response steps.
A remediation sequence that avoids replacing the SIEM
Most of these gaps are closed by configuration, onboarding and discipline, not by new platforms. A workable order is:
- Inventory and map. Document critical assets, the log sources that should cover them, and current status.
- Fix time and normalisation. These are inexpensive changes that make every later source more useful.
- Onboard identity, privileged and remote access sources. These close the largest timeline gaps.
- Establish source-health alerting and retention controls. This turns coverage into something you can prove continuously.
- Align detection use cases to available data. Then rehearse a scenario end to end and keep the evidence.
Keep the evidence from each step. Assessors respond to records showing what was done, when, and by whom.
A note on ECC-2:2024
If your last assessment was against ECC-1:2018, do not assume your earlier logging work carries over unchanged. The structure and several requirements changed in the 2024 version. The practical approach is to map what you already have to the new controls and address only what is new or different, rather than restarting the programme.
How CISO Consulting helps
CISO Consulting provides compliance assessment, remediation and self-assessment support for the NCA Essential Cybersecurity Controls. Our work is built around readiness for ECC-2:2024, control by control.
The assessment takes 6–10 weeks and gives you control-by-control compliance status with evidence. You receive a compliance assessment report, a remediation plan and tracker, a policy and procedure set, self-assessment submission support and an executive summary.
The remediation plan sets out owners, dates and effort, so the logging fixes described above can be sequenced against your own priorities. If you complied with ECC-1:2018, we map your existing compliance to the new controls so you only address what is actually new or different. The result is a baseline you can re-measure every year.
If you are preparing for assessment and want an honest view of how your logging architecture would stand up, we would be glad to start that conversation.